8
Make-up vessel
or tank
Automatic
air-vent
Non-return
valve
Stopcock
5.0 metres minimum
Heating
return
Fig. 5
Fig. 6
Fig. 6A
Fig. 6B
Default screws position of fixing jig: No. 3
3.6.8 FREQUENT FILLING
Frequent filling or venting of the system may be indicative of a leak.
Care should be taken during the installation of the appliance to
ensure all aspects of the system are capable of withstanding
pressures up to at least 3 bar.
3.7 ELECTRICAL SUPPLY
The appliance is supplied for operation on 230V @ 50Hz electrical
supply; it must be protected with a 3-amp fuse. The method of
connection to the mains electricity supply must allow for complete
isolation from the supply. The preferred method is by using a
double-pole switch with a contact separation of at least 3,5mm (3°
high-voltage category). The switch must only supply the appliance
and its corresponding controls, i.e. time clock, room thermostat, etc.
Alternatively an un-switched shuttered socket with a fused 3-pin
plug both complying with BS 1363 is acceptable.
3.8 TIMBER FRAMED BUILDINGS
If the appliance is to be fitted in a timber framed building, it should
be fitted in accordance with the Institute of Gas Engineers publication
(IGE/UP/7) ‘Guide for Gas Installations in Timber Frame Buildings’.
3.9 INHIBITORS
Vokèra recommend that an inhibitor - suitable for use with
aluminium heat exchangers - is used to protect the boiler and
system from the effects of corrosion and/or electrolytic action. The
inhibitor must be administered in strict accordance with the
manufacturers instructions*.
*Water treatment of the complete heating system - including the
boiler - should be carried out in accordance with BS 7593 and the
Domestic Water Treatment Association’s (DWTA) code of practice.
3.10 SHOWERS
If the appliance is intended for use with a shower, the shower must
be thermostatically controlled and be suitable for use with a
combination boiler.
Hot water outlet
Cold water inlet
stopcock/filling
valve
Gas
cock
Filling loop
C/H flow
valve
C/H return
valve
Safety
valve outlet