VOKERA Linea Manual de Serviço Página 35

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 52
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 34
33
Linea
A2
REPLACE
CONTROL
BOARD
FUSE OK
CHECK FUSES
F1 AND F2 ON
CONNECTION
BOARD
RECHECK SUPPLY FUSE
& CONNECTORS TO
BOILER TERMINALS
IS
RED LED
FLASHING
REPLACE THE
BICOULORED
LED ASSEMBLY
MAINS
PRESENT BETWEEN
M16.L & M16.N ON
CONTROL
BOARD
RESTART THE
TEST
REPLACE FUSE
BICOULORED
LED ASSEMBLY
OK
A4
FAULT
CODE
SHOWING
REPLACE THE
DIGITS BOARD
5 Vdc
BETWEEN
TERMINALS
M9.1 & M9.2 ON
CONTROL
BOARD
CHECK AND/OR
REPLACE WIRING
OR CONNECTIONS
WITH DISPLAY BOARD
5 Vdc
BETWEEN TERMINALS
M2.1 & M2.2 ON DISPLAY
BOARD
REPLACE DIGITS
BOARD
FAULT
CODE 01
SHOWING
SWITCH ON/OFF
SELECTOR TO
OFF POSITION
SWITCH MODE
SELECTOR TO
DHW POSITION
GREEN LED
LIGHT
RESTART THE
TEST
IGNITION
CONTROL OK
REPLACE
CONTROL
BOARD
REPLACE
IGNITION
CONTROL
FAULT
CODE 02
SHOWING
GREEN LED
LIGHT
RESTART THE
HIGH LIMIT STAT
CHECK WIRING AND
CONNECTIONS ,HIGH
LIMIT THERMOST. AND
CONTROL BOARD
YES
NOYES
NO
NO
YES
YES
YES
NO
NO
YES
NO
YES
YES
YES
NO
NO
NO
NO
YES
YES
YES
NO
Vista de página 34